Enhanced TDS
Identification & Functionality
- Cleaning Ingredients Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- HII Features
- Product Highlights
- Excellent detergency: Can be used in hard surface cleaners and general cleaners. In formulations that contain alcohol ethoxylates then use BioLoop 84L as a green alternative. Also the SDS classifications will help ensure negative impact on the hazard classification of the end product.
- Excellent wetting on glass: Can be used in a new generation of bio-based glass cleaners.
Applications & Uses
- Markets
- Applications
- Home Care Applications
- I&I Cleaning Applications
- Applications
The normal grade of BioLoop surfactants are aimed at standard industrial-based processes in which clarity in an aqueous medium isn’t a necessity. The PG versions which denotes our purified grades are for industries in which clarity in aqueous mediums is essential.
Normal Grades:
- Oils and Lubricants
- Emulsion Polymers
- Agrochemical Additives
- Textiles Auxiliaries
- Hand and Floor Wipes
PG Versions:
- Personal Care
- Cosmetics
- Household Products
Properties
- Physical Form
- Appearance
- Light amber liquid (at 25°C)
- Odor
- Characteristic
- Typical Properties
Value Units Test Method / Conditions Bio-based Carbon Content 99.36 % - Hydrophilic-Lyphophilic Balance Value 14.9 - - Viscosity (at 25°C) 539 cPs Specific Gravity (at 20°C) 1.08 - - Pour Point min. 150 °C - Flash Point 39.2 °C Closed Cup Surface Tension (0.1% aqueous) -8 mN/m - - Specifications
Value Units Test Method / Conditions Color max. 5 Gardner - Cloud Point (1% aqueous) 80 - 88 °C - Solid Content 74 - 76 % - pH (5% aqueous) 6 - 8 - -
Technical Details & Test Data
- Foaming Profile
Test method: A 0.1% solution is prepared and aerated for 30 seconds and then stopped. The degree of foaming is assessed initially and then after 1, 3 and 5 minutes.
- Detergency Profile
Test method: A formulated soil is applied to a painted disk and then aged in an oven. The disk is then soaked in a detergent solution for 10 minutes and then rotated for a further 5 minutes. The % soil removal is then measured.
Sample % soil removal Blank 20.1 BioLoop 84L 81.5 - Substrate Wetting
Test method: A 0.5% solution is prepared and is dropped onto various substrates. The contact angle is then measured using a goniometer. The angle is measured initially and then after 5 seconds. The lower the angle the better the product wets the substrate.
Glass:
Sample Contact Angle Initial Contact Angle - 5 sec
Water 46 45 BioLoop 84L 17 8
Packaging & Availability
- Regional Availability